Products

Enzymes for Research, Diagnostic and Industrial Use

Immobilized Alkaline Phosphatase on G3m

Cat No.
NATE-1774
Description
G3m: 24 μg (100 units) phosphatase per CR-column immobilized on dextran.
Nr. 15 Storage buffer: 50 mM Tris/HCl, pH 8. 0
Nr. 18 Reaction buffer: 50 mM Tris/HCl, 0.1 mM ZnCl2, 1 mM MgCl2 pH 8. 0
For longer molecules use higher temeratures (37 °C up to 50 °C) Take the column in an incubator or pre-warmed buffers
Nr. 17 Washing buffer: 50 mM Tris/HCl, 1 M NaCl, pH 8. 0
Source
Calf intestine
Enzyme Commission Number
EC 3. 1. 3. 1
Storage
4 °C
Synonyms
Alkaline phosphatase; ALP; ALKP; ALPase; Alk Phos; EC 3. 1. 3. 1; Alkaline phosphomonoesterase; Glycerophosphatase; Phosphomonoesterase
Protocol
1. Dilute delivered buffers (at least 2 ml each) with sterile doubly distilled water.
For 1 application you need:
2 ml 5x reaction buffer and 8 ml doubly distilled water
2 ml 5x washing buffer and 8 ml doubly distilled water
1 ml 10x storage buffer and 9 ml doubly distilled water
The substrate should be in reaction buffer
2. Equilibrate the CR-column with 10 ml reaction buffer.
Fill 10 ml reaction buffer into a syringe, let the reaction buffer run through the column by gravity to the upper filter. In case the buffer runs very slowly, apply pressure by a syringe.
3. Load substrate solution in reaction buffer.
Small volumes (< 70 μl): spin the CR-column 5 seconds in a benchtop centrifuge (2000 rpm are sufficient).
Let the substrate solution enter the matrix material.
Larger volumes: Let the substrate solution run through the column.
Flow-rate: up to 70 μl/minute
Keep the substrate in the column for about 1 minute at room temperature. Higher turn-over is obtained when the substrate is applied to the column again or incubated for longer times.
4. Elute the product solution.
Small volumes (< 70 μl): centrifuge the product out of the column.
Larger volumes: Let the substrate run through the column and spin the residual solution out of the matrix
Notice: Molecules < 700 Dalton have to be eluted with 7 ml reaction buffer.
It does not harm the columns if they run dry.
5. Wash the column with 10 ml washing buffer.
6. Equilibrate the column with 10 ml storage buffer.
Store the column at 4 °C.
Never freeze a CR-column!
Download Datasheet:



Inquiry
Realted Products
Catalog
ProductName
EC No.
CAS No.
Source
Price
CatalogNATE-1634
EC No.EC 3.1.3.1
CAS No.
SourceInsect cell (Baculovirus) and fused to His-tag at C-terminus
CatalogNATE-1664
EC No.EC 3.1.3.1
CAS No.
SourceBaculovirus
CatalogNATE-1871
EC No.EC 3.1.3.1
CAS No.9001-78-9
SourceBovine Liver
CatalogDIA-181
EC No.EC 3.1.3.1
CAS No.9001-78-9
SourceMicroorganism
+ See More >>
Online Inquiry
Name:
*Phone:
*E-mail Address:
Country:
Company/Institution:
*Products or Services Interested:
Quantity:
Project Description:
Our Products are Not Intended for Private Therapeutic Use!
*Verification Code:
Please input "enzymes"(case insensitive) as verification code.

Welcome! For price inquiries, please feel free to contact us through the form below through the form on the left side. We will get back to you as soon as possible.

Sitemap  Privacy Policy
Copyright ©2011 - 2017 Creative Enzymes.
Contact Us 45-1 Ramsey Road, Shirley, NY 11967, USA
Email: info@creative-enzymes.com
Tel: 1-631-562-8517 1-631-448-7888
Fax: 1-631-938-8127
Distributors To view the contact information for a specific location, select the desired country: