Enzymes for Research, Diagnostic and Industrial Use

Immobilized Endoproteinase Glu-C on G3m

Cat No.
Endoproteinase Glu-C hydrolyzes peptide and ester linkages specifically at the carboxyl end of glutamic acid (-Glu/-X; in ammonium carbonate pH 7. 8, or ammonium acetate pH 4. 0, buffer A) or of glutamic and aspartic acid (-Glu/-X and -Asp/-X; in phosphate buffer pH 7. 8, buffer B).
G3m: 25 µg (22 units) endoproteinase Glu-C per CR-column immobilized on dextran.
This CR-column cuts at least 12 µg tubulin or 5 µg BSA per application in phosphate buffer.
Nr. 7 Storage buffer: 50 mM Tris/HCl at pH 7. 5, 5 mM EDTA.
Nr. 31 Reaction buffer: 25 mM NH4-acetate, pH 4. 0 (see above)
Nr. 32 Washing buffer: 25 mM NH4-acetate, pH 4. 0, 1 M NaCl
Nr. 62 Reaction buffer: 50 mM phosphate buffer, pH 7. 8 (see above)
Nr. 63 Washing buffer: 50 mM phosphate buffer, pH 7. 8, 1 M NaCl
Staphylococcus aureus
Enzyme Commission Number
EC 3. 4. 21. 19
4 °C
EC 3. 4. 21. 19; Staph aureus V8 Protease; Protease, Staph aureus (Endoproteinase Glu-C); Glutamyl endopeptidase; V8 proteinase, endoproteinase Glu-C; staphylococcal serine proteinase
1. Dilute delivered buffers (at least 2 ml each) with sterile doubly distilled water.
For 1 application you need
1 ml 10x reaction buffer and 9 ml doubly distilled water
2 ml 5x washing buffer and 8 ml doubly distilled water
1 ml 10x storage buffer and 9 ml doubly distilled water
The substrate should be in reaction buffer
2. Equilibrate the CR-column with 10 ml reaction buffer.
Fill 10 ml reaction buffer into a syringe, let the reaction buffer run through the column by gravity to the upper filter. In case the buffer runs very slowly, apply pressure by a syringe.
3. Load substrate solution in reaction buffer.
Small volumes (< 70 µl): spin the CR-column 5 seconds in a benchtop centrifuge (2000 rpm are sufficient). Let the substrate solution enter the matrix material.
Larger volumes: Let the substrate solution run through the column.
Flow-rate: up to 70 µl/minute
Keep the substrate in the column for about 1 minute at room temperature. Higher turn-over is obtained when the substrate is applied to the column again or incubated for longer times.
4. Elute the product solution.
Small volumes (<70 µl): centrifuge the product out of the column.
Larger volumes: Let the substrate run through the column and spin the residual solution out of the matrix
Notice: Molecules < 700 Dalton have to be eluted with 7 ml reaction buffer.
It does not harm the columns if they run dry.
5. Wash the column with 10 ml washing buffer.
6. Equilibrate the column with 10 ml storage buffer.
Store the column at 4°C. Never freeze a CR-column!
Download Datasheet:

Related Products
EC No.
EC No.EC 3. 4. 21. 19
SourceStaphylococcus aureus
CAS No.137010-42-5
SourceStaph aureus V8
EC No.
CAS No.66676-43-5
SourceBacillus subtilis
Online Inquiry
*E-mail Address:
*Products or Services Interested:
Project Description:
Our Products are Not Intended for Private Therapeutic Use!
*Verification Code:
Please input "enzymes"(case insensitive) as verification code.

Welcome! For price inquiries, please feel free to contact us through the form below through the form on the left side. We will get back to you as soon as possible.

Sitemap  Privacy Policy
Copyright ©2011 - 2018 Creative Enzymes.
Contact Us 45-1 Ramsey Road, Shirley, NY 11967, USA
Tel: 1-631-562-8517 1-516-512-3133
Fax: 1-631-938-8127
Distributors To view the contact information for a specific location, select the desired country: